Industrial Products & Services
: Fasteners :
LockBolts :
Metric Huck-Fit® :
Inspection Data
Inspection Data

Should 'A' or 'B' dimensions exceed the given values, the fastener is out-of-grip. A 'C' dimension less than the given value indicates an incomplete swage. A 'D' dimension greater than the given values indicates an incorrect or worn anvil on the installation tool.

| Dia | A max | B max | C min | D max | | 12mm | .60 | 10.6 | 14.0 | 18.3 | | 16mm | .60 | 10.6 | 17.7 | 24.1 | | 20mm | .60 | 10.6 | 21.2 | 30.3 | | | | A properly installed fastener will possess the dimensions given here. Visual inspection is sufficient. |
|
 |




|
|