Installation Inspection

Pin Position & Swage Gage for pull type LHP Lockbolts

| Accept | Reject | Accept | Reject | Points Y1 touch pin. Grip is not over Maximum | Points Y1 do not touch pin. Grip is over maximum. Points T1 touch collar- collar not swaged sufficiently | Points Y2 do not touch pin. Grip is not under minimum. Points T2 do not touch collar-collar is swaged sufficiently | Points Y2 touch pin. Grip is under minimum and /or points T2 touch collar-collar is not swaged sufficiently |
| Nom Dia. | HUCKCOMP® Part Numbers | Y1 Touch Go | Y2 Touch No- Go | Z | R | T1 Touch Go | T2 Touch No-Go | Gage Number | | 5/32 (05) | LHPL7SC-V( )C( ) LHPL8SC-V( )C( ) LHPL9SC-V( )C( ) LHPL9SP-V( )C( ) LHPL12SP-V( )C( ) | .140 | .264 | .125 | .234 | .095 | .062 | HG159-05 | | 3/16 (06) | .145. | .265 | .153 | .262 | .099 | .067 | HG159-06 | | 1/4 (08) | .203 | .334 | .210 | .344 | .132 | .100 | HG159-08 | | 5/16 (10) | | | .260 | .436 | | | HG159-10 | | 3/8 (12) | | | .323 | .512 | | | HG159-12 |
|