Installation Inspection

Pin Position & Swage Gage for pull type LHP Lockbolts


Accept

Reject

Accept

Reject

Points Y1 touch pin.
Grip is not over Maximum
Points Y1 do not touch pin. Grip is over maximum. Points T1 touch collar- collar not swaged sufficiently
Points Y2 do not touch pin. Grip is not under minimum. Points T2 do not touch collar-collar is swaged sufficiently
Points Y2 touch pin. Grip is under minimum and /or points T2 touch collar-collar is not swaged sufficiently


Nom
Dia.

HUCKCOMP®
Part Numbers

Y1 Touch
Go

Y2 Touch
No- Go

Z

R

T1 Touch
Go

T2 Touch
No-Go

Gage
Number

5/32 (05)


LHPL7SC-V( )C( )
LHPL8SC-V( )C( )
LHPL9SC-V( )C( )
LHPL9SP-V( )C( )
LHPL12SP-V( )C( )
.140
.264

.125

.234

.095
.062

HG159-05

3/16 (06)

.145.

.265

.153

.262

.099

.067

HG159-06

1/4 (08)

.203
.334

.210

.344

.132
.100

HG159-08

5/16 (10)

   

.260

.436

   

HG159-10

3/8 (12)

   

.323

.512

   

HG159-12