Pin Position & Swage Gages/Installed Fastener Inspection Procedure

Pin Position & Swage Gages/Installation Inspection
Titanium LGP® Lockbolts Pull-Type

Accept Points Y1 touch pin. Grip is not over maximum | Reject Points Y1 do not touch pin. Grip is over maximum and/or pointsT1 touch collar - collar not swaged sufficiently | Accept Points Y2 do not touch pin. Grip is not under minimum. Points T2 do not touch collar - collar is swaged sufficiently | Reject Points Y2 touch pin. Grip is under minimum and/or points T2 touch collar - collar not swaged sufficiently |
| For Fasteners Installed with 3SLC-C Aluminum Collars | | Diameter | Y1 | Y2 | Z | R | T1 | T2 | Gage No. | | .164 (05) | .132 | .236 | .124 | .234 | .038 | .111 | HG110-05 | | .190 (06) | .135 | .249 | .152 | .262 | .030 | .112 | HG110-06 | | .250 (08) | .194 | .300 | .209 | .344 | .057 | .138 | HG110-08 | | .312 (10) | .253 | .366 | .259 | .436 | .071 | .144 | HG110-10 | | .375 (12) | .305 | .418 | .322 | .512 | .102 | .171 | HG110-12 | | .437 (14) | | | | | | | HG110-14 | | For Fasteners Installed with SLC-EU CRES Collars | | .164 (05) | .132 | .244 | .125 | .234 | .058 | .138 | HG137-05 | | .190 (06) | .136 | .245 | .140 | .262 | .051 | .123 | HG137-06 | | .250 (08) | .195 | .302 | .200 | .344 | .090 | .164 | HG137-08 |
Grip Thickness Gauging Gage number 112731 is available for LGP® grip thickness. This gage measures in 1/16-inch increments plus overlap capability. Gage number 118947 is available for LGP® grip thickness. This gage measures in 1/16-inch increments.
|